HIU TECH
Cooling / CIU & FCU

Cooling
servicing.

Specialist servicing and technical diagnostics for the Cooling Interface Units and Fan Coil Units serving apartments within modern residential developments.

Riverside residential towers in Vauxhall, London

CIU servicing

A Cooling Interface Unit connects the apartment to the development's communal chilled-water network. Servicing assesses how the unit responds to cooling demand, the condition of its heat transfer surfaces and strainers, and the behaviour of the control valve and actuator that regulate flow.

Where cooling performance in the apartment is below expectation, the unit is assessed in context: what the network is delivering, what the unit is passing, and what the terminal equipment is able to achieve with it.

FCU — Fan Coil Units

Specialist servicing, diagnostics and maintenance of Fan Coil Units serving heating and cooling systems within modern residential properties.

FCU technical servicing includes assessment of fan operation, motors, coils, filters, control valves, actuators, condensate systems, sensors, thermostatic controls and associated electrical components.

Where system performance requires investigation, HIU TECH can assess temperatures, airflow, control operation and valve response to establish the technical cause before recommending repair or component replacement. Condensate and drainage faults are treated as a technical priority because of their consequences elsewhere in the building.

  • Fan operation, fan motors and speed control
  • Coil condition and heat transfer
  • Filter condition and replacement
  • Control valves and actuators
  • Condensate tray, drainage and pump
  • Sensors, thermostatic controls and associated electrical components

CIU and FCU: how they work together

A CIU (Cooling Interface Unit) and an FCU (Fan Coil Unit) are different pieces of equipment. The CIU is the connection between the apartment and the development's chilled-water network; the FCU is the terminal unit that moves air across a coil to deliver cooling, and in some installations heating, into the room.

Where both form part of the apartment cooling arrangement, FCU servicing and CIU servicing are assessed together, because the output of the Fan Coil Unit depends on what the Cooling Interface Unit is supplying to it.

Technical diagnostics

Cooling complaints in apartments frequently originate away from the equipment the resident can see. Flow temperature at the interface, valve position, actuator behaviour, air-side performance and control configuration are measured and compared before any component is recommended for replacement.

Both CIU and FCU work requires attendance. Diagnosis is based on measured temperature, flow and control behaviour in the installed system.

Associated components

Pumps, control valves, actuators, sensors and controls are serviced and diagnosed as part of the cooling system rather than as separate trades.

Request cooling servicing.

Technical attendance is arranged directly with the office. Call or send the system details and we will confirm the visit.